 NXI150 Series
DC-DC CONVERTERS
Single output
81 A DC-DC Non-Isolated Converters NEW Product 1
* Meets VRM9.1 specification * Microprocessor voltage identification input - 5 Bit VID input - 1.10 Vdc to 1.85 Vdc in 25 mV steps * Up to 50 A/s load transient * Democratic current sharing, no need for master/slave configuration * Remote sense for improved load regulation * Vertical plug-in to standard motherboard connector with or without retention latch * Available RoHS compliant
The NXI150 non-isolated dc-dc converter is designed to meet the exceptionally fast transient response requirements of today's microprocessors and fast switching logic in a compact size at a very affordable price. Advanced circuit techniques, component selection and placement optimization, state-of-the-art thermal packaging, and Surface Mount Technologies provide a high power density, highly reliable, and very precise voltage regulation system for advanced microprocessors. Multi-phase power conversion techniques allow the NXI converters to lead the industry with regard to conversion efficiency without adding unneccesary complexity. On-board active current sharing circuit guarantees the current sharing specification is met during static and dynamic load conditions. All specifications are typical at nominal input, full load at 25 C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Voltage adjustability Output setpoint accuracy Vout Ripple and noise (See Notes 1 and 2) Transient response peak dev. settling time Short-circuit protection 20 MHz bandwidth See Note 3 1.10-1.85 Vdc 0.8% 15 mV pk-pk 50 mV 25 s Continuous current limit, foldback automatic recovery
GENERAL CHARACTERISTICS Efficiency Switching frequency Standards Weight MTBF Mating connector ENVIRONMENTAL SPECIFICATIONS Maximum temperature shock Temperature shock Humidity (Non-condensing) Altitude Shock Operating Operating Non-operating Operating Storage Operating Storage Operational and non-operational Operational and non-operational 5 C/10 min. 10 C/hour 20 C/hour 85% RH 95% RH 10,000 feet max. 50,000 feet max. 50 G 11 ms, half sine wave 0.02 G2/Hz max. ESD 15 kV ESD 25 kV 0 C to +60 C -40 C to +100 C Telcordia SR-332 1.5 V output @ 65 A Fixed (See Note 4) 85% 1 MHz
94V-0 Flammability rating 70 g (2.46 oz) 1,800,000 hours (See Note 5)
INPUT SPECIFICATIONS Input voltage range Input current 12 Vin nominal Operation No load Remote OFF 11.0-12.6 Vdc 16.2 A max. 250 mA 45 mA max. 10.45 V typ. 8.55 V typ. Nominal line 10 ms max. Ref. to -input >1.8 Vdc <0.8 Vdc
UVLO turn ON voltage UVLO turn OFF Voltage Start-up time OUTEN Logic compatibility ON OFF
Open circuit
Vibration (See Note 6)
Electrostatic discharge Operating IEC61000-4-2 (See Note 7) non-operating Thermal performance (See Note 8) Operating ambient temperature non-operating
Filename: NXI150.PDF Rev (03): 20 Dec 2005
NXI150 Series
DC-DC CONVERTERS
INPUT VOLTAGE 12 Vdc OUTPUT VOLTAGE 1.10-1.85 Vdc OVP 120% of VID setting OUTPUT CURRENT (MIN) 0A
Single output
2 NEW Product
81 A DC-DC Non-Isolated Converters
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT (MAX.) 81 A
EFFICIENCY (TYP.) 85%
REGULATION LOAD 0.95 mV/A
MODEL NUMBER (9,10) NXI150-12P1V8CY
TABLE 1: PIN CONNECTIONS PIN NO. FUNCTION PIN NO. FUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Vin+ Vin+ Vin+ Vin+ Reserved Key VID3 VID1 Reserved PWRGD Vo senReserved VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ Vo62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 VinVinVinVinVRM-pres VID4 VID2 VID0 Ishare OUTEN Vo sen+ Reserved Vo+ Vo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVo+ VoVID4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
TABLE 2: VOLTAGE IDENTIFICATION (VID) CODES VID3 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 VID2 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 VID1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 VID0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 VDAC Off 1.100 1.125 1.150 1.175 1.200 1.225 1.250 1.275 1.300 1.325 1.350 1.375 1.400 1.425 1.450 1.475 1.500 1.525 1.550 1.575 1.600 1.625 1.650 1.675 1.700 1.725 1.750 1.775 1.800 1.825 1.850
Filename: NXI150.PDF Rev (03): 20 Dec 2005
NXI150 Series
DC-DC CONVERTERS
0.255 (6.48) Max
1 62
Single output
81 A DC-DC Non-Isolated Converters NEW Product 3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
31 32
0.250 (6.35) Max
3.800 (96.52)
2.300 (58.42)
0.700 (17.78)
62
32
0.936 (23.77)
0.042 (1.07) 1.243 (31.57) 0.093 (2.36)
C L
30 EQ Spaces @ 0.100 (2.54) each Equals 3.000 (76.20) TOL Non-Accum
0.063 0.007 THICK FR-4 2-Sided CKT BD W/Gold Plated 30" Connector Fingers
0.307 (7.80)
3.186 (80.92)
Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Place 0.02 3 Place 0.010
Figure 1: Mechanical Drawing
Notes
1 2 3 4 5 6 7 Recommended output capacitance, 8 x 560 F/4 V OSCON and 10 x 4.7 F/6.3 V MLCC. 15 mV pk-pk ripple. Vin = 12 V, Vout = 1.5 V, Iout = 65 A. 125 mV peak deviation when slewing load from no load to full load at 50 A/s. Recommended capacitors (per Note 1) required across output. Each phase operates at a fixed 250 kHz. Effective fundamental output frequency is 1 MHz / 4 phases each at 250 kHz interleaved. Recommended mating connector is AMP 1489162-1 or equivalent. From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all axes. When included in the users system ESD event shall cause no out-ofregulation conditions.
Notes Cond
Please consult your local application support for: Longform Datasheet and Application Note for the de-rating curves . 9 The `Y' suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free) compliant. 10 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative.
(11,12)
8
Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult your local application support for: Application Note Longform Datasheet
www.artesyn.com
Filename: NXI150.PDF Rev (03): 20 Dec 2005